4000A 11kv Indoor Three Phases Isolation Switch with Motor Operating Mechanism

Luogo di origine Wenzhou
Marca QIUPU
Certificazione IEC
Numero di modello GN22-12/4000A
Quantità di ordine minimo 10pcs
Imballaggi particolari WOODENS
Tempi di consegna 7 giorni
Termini di pagamento T/T, Western Union
Capacità di alimentazione 50000 pezzi/mese

Contattimi gratis campioni e buoni.

whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

Se avete di preoccupazione, forniamo la guida in linea di 24 ore.

x
Dettagli
Tensione di velocità 11kv Valuta corrente 4000A
Corrente stabile calda 12.5kA/4S Corrente di Satble di movimento 31.5kA/4S
Largo 480 mm Breve corrente 40KA
Lasciate un messaggio
Descrizione di prodotto

4000A 11kv Indoor Three Phases Isolation Switch with Motor Operating Mechanism

 

 

        1. We are specialty on epoxy resin medium voltage and high voltage components, such as 10KV, 24 KV and 40.5KV Circuit Breaker , Load breaker switch , Disconnecting Switch , Epoxy resin switchgear bushing , contactor box , insulators and transformer . 630A, 1250 A ,2500A , 3150A and 4000A contact box , club contact , fix contact, arm contact and jaw contact . 630A and 1250A VS1 circuit breaker . 630A and 1250A ZN85-40.5 circuit breaker . 12KV and 24KV earth switch. KYN28A-12 and KYN61 high voltage switchgear components!

 

        2. The Indoor high voltage isolation switch GN22-12(C) is use for three phase alternating current 50Hz , rate voltage is 12kV .

        3. Altitude is less than 1000 M .

 

        4. It is mainly used for "isolation power supply, turndown operation, for connecting and cutting off small current circuit", without arc extinguishing function.
The isolation switch, usually referred to as the high voltage isolation switch, is rated voltage above 1kV isolation switch, is the most used high voltage switch electrical appliances, working principle and structure is relatively simple, but because of the high usage, high reliability requirements, the design, construction and safe operation of power substation, power plant has a great impact.

 

 

Item Technical data
Rated voltage (KV)     12    
Rated frequency(Hz) 50
Insulator(capacity) insulating Frequency withstand voltage 5 min (KV)     42    
Frequency withstand voltage 1 min (V) 2000
Lighting impulse withstand voltage (KV)     75    
humitity 90%
light frequency voltage 85kV
   

 

        4000A 11kv Indoor Three Phases  Isolation Switch with Motor Operating Mechanism 04000A 11kv Indoor Three Phases  Isolation Switch with Motor Operating Mechanism 14000A 11kv Indoor Three Phases  Isolation Switch with Motor Operating Mechanism 2