Epoxy Resin Medium-Voltage 75X190 24kV Support Capacitor Insulator with 80pF

Luogo di origine Wenzhou
Marca QIUPU
Certificazione IEC
Numero di modello ZN8-24Q/75*190/80pF
Quantità di ordine minimo 100 pezzi
Imballaggi particolari Cartoni
Tempi di consegna 7 giorni
Termini di pagamento T/T, Western Union
Capacità di alimentazione 100.000 pezzi/mese
Dettagli
Materiale Resina da colata Colore Rosso/Marrone
Altezza 190 mm Distanza di crepaccio 320 mm
Tensione di tasso 24KV Resistenza alla flessione 8 kN
Lasciate un messaggio
Descrizione di prodotto

Epoxy Resin Medium-Voltage 75X190 24kV Support Capacitor Insulator with 80pF

 

Features:

 

 

 

A . First, use the electric car. Before the grounding switch, pull the circuit breaker car out of the cabinet, then push into the electric check car, the circuit grounding switch after checking that there is no voltage.


B. Second, open the door. When the circuit breaker is in the test position and the charged display device detects that the line has no voltage, turn on the door and check that there is no voltage, then close the ground switch.

 

C. Third, depending on the line side electric display of the role of locking device. As long as the line side electric display latching device indicates no power, latching open, the operation of the grounding switch.


Method A large amount of operation, equivalent to no electric car power outage operation, only bus and grounding operation, the use of special electric car and ground hand car. Method 2 is adopted by some power departments, the operation procedure is complicated.


Methods The third method is to use a more common way. When the circuit breaker is in the test position, the grounding switch can only be met if the circuit side has no electricity and the electric display device is electrically and normally, and the locked electromagnet is electrically and normally. Any failure or loss of power in a live display device or locked electromagnet will not be able to close the gate. At present, there are no accidents of electrically connected ground switch due to locking fault of electric display device. When the charged display sensor fails or breaks, it is reflected through the indicator light on the charged display.

 

Item Technical data
Rated voltage (KV)       24  
Rated frequency(Hz) 50
Insulator(capacity) insulating Frequency withstand voltage 5 min (KV)       68  
Frequency withstand voltage 1 min (V) 2000
Lighting impulse withstand voltage (KV)       125  
Local discharge (pc) ≤10
Dispute bend (N) ≥10000
   

   Epoxy Resin Medium-Voltage 75X190 24kV Support Capacitor Insulator with 80pF 0  

     Epoxy Resin Medium-Voltage 75X190 24kV Support Capacitor Insulator with 80pF 1